Home About us Editorial board Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 640
  • Home
  • Print this page
  • Email this page
ARTICLE
Year : 2011  |  Volume : 18  |  Issue : 1  |  Page : 48-50

Biopty Gun-Driven Versus Manually-Driven Tru-cut Prostate Biopsy; any difference in the yield? Ilorin Experience


Division of Urology, Department of Surgery, University of Ilorin Teaching Hospital, Ilorin, Nigeria

Correspondence Address:
Dr. Abdulwahab Akanbi Ajape
P.O. Box 4850, Ilorin. Kwara State
Nigeria
Login to access the Email id

Source of Support: None, Conflict of Interest: None


Rights and PermissionsRights and Permissions

Objectives: To report the outcome in the yield of two techniques of prostate biopsy. Patients and methods: The study was a retrospective review of the experience with digitally guided trans-rectal Tru-cut needle biopsy of the prostate using manually- driven and the Biopty gun-driven methods. The record of patients who had undergone prostate biopsy was retrospectively reviewed from January 2000 to December 2007. Data extracted included the age, the year of biopsy and/or the method of biopsy, the status of the operator and the histology report of tissue obtained. Data was analysed with the aid of SPSS (Version 11.0) software, the Chi - square test was calculated for the variables and statistical significant P value at P < 0.05. Results: A total of 292 prostate biopsies were undertaken during the review period. One hundred and ninety were gun-driven (65.1%) while 34.9% were manually-driven. A total of 55.5% of the specimens were benign prostate hyperplasia while 28.4% were adenocarcinoma of the prostate on histological examination. Thirty-six per cent of the tissues obtained from manually-driven biopsy were not representative as compared with only 4% of tissue from gun-driven biopsies. There was a significant correlation between the method of biopsy and the likelihood of tissue representativeness for histological appraisal (P<0.0001). Conclusion: There was a significant difference in the tissue yield between manually- driven and the gun-driven Tru-cut needle biopsy of the prostate.. Biopty-driven Tru- cut needle sampling of the prostate is the recommended procedure in this environment.


[PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed860    
    Printed10    
    Emailed0    
    PDF Downloaded76    
    Comments [Add]    

Recommend this journal